Is it difficult for you to decide to purchase DELL EMC D-PEXE-IN-A-00 exam dumps questions? CertQueen provides FREE online Dell PowerEdge XE9680 and XE8640 Install D-PEXE-IN-A-00 exam questions below, and you can test your D-PEXE-IN-A-00 skills first, and then decide whether to buy the full version or not. We promise you get the following advantages after purchasing our D-PEXE-IN-A-00 exam dumps questions.
1.Free update in ONE year from the date of your purchase.
2.Full payment fee refund if you fail D-PEXE-IN-A-00 exam with the dumps

 

 Full D-PEXE-IN-A-00 Exam Dump Here

Latest D-PEXE-IN-A-00 Exam Dumps Questions

The dumps for D-PEXE-IN-A-00 exam was last updated on Jun 09,2025 .

Viewing page 1 out of 0 pages.

Viewing questions 1 out of 3 questions

Question#1

A deployment engineer arrives on-site to install an XE9680 server. The server lift does not have the ability to maneuver beneath the XE9680 shipping pallet.
How many people must you have to physically pick up the server to place it on the lift shelf?

A. 4. The server is heavy, and the lift shelf does not rest on the floor.
B. 3. Two people are needed to tilt the server while the third person slides the shelf beneath the server.
C. 2. At least one person on each side is needed to pick up the server and place on the lift.
D. 1. They can tilt the server and slide the lift underneath.

Explanation:
Weight and Size of the PowerEdge XE9680:
The Dell PowerEdge XE9680 server is designed for high performance, which often results in a larger and heavier form factor. Handling such servers typically requires multiple people to ensure safety
and prevent damage.
Ergonomic Considerations:
Due to its weight and size, it is crucial to follow proper ergonomic practices when lifting and moving the server. This minimizes the risk of injury and ensures the server is handled safely. Number of People Required:
For the XE9680, it is recommended to have four people when physically picking up the server to
place it on the lift shelf. This recommendation is based on the server's weight and the need to
maneuver it safely onto the lift.
Safety and Coordination:
Each person should position themselves on one side of the server, ensuring an even distribution of
weight. This coordinated effort helps in lifting the server evenly and reducing the risk of dropping or
mishandling it.
Procedure for Lifting:
Two individuals should position themselves at the front corners, and two at the rear corners of the server. On a coordinated count, all four should lift the server together and place it gently onto the lift shelf.
The lift shelf should be stable and able to support the weight of the server once it is placed on it.
Using the Lift:
Once the server is on the lift shelf, it can be maneuvered into the desired position in the rack. Ensure that the lift is rated for the weight of the XE9680 to avoid any mechanical failures. Reference to Official Documentation:
Dell’s installation guides and service manuals typically provide guidelines on the number of
personnel required for handling large and heavy servers, ensuring both safety and compliance with
best practices.
Reference: Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides detailed guidelines on handling and installing the XE9680 server, including the recommended number of personnel required for safe handling.
Dell EMC Technical Specifications Guide: Offers insights into the physical dimensions and weight of the PowerEdge XE9680, informing the need for multiple personnel for safe handling and installation.

Question#2

A deployment engineer is installing eight PowerEdge XE9680 servers. Two servers will be installed in each of four racks. The data center managers must plan for the power needed to supply power to the four racks.
What power consumption information can the deployment engineer give the data center manager?

A. Each rack must have at least 6 PDUs for power high availability.
B. Each server has four 2800-Watt, 15.6 Amp PSUs.
C. Each rack must power 12, 2800-Watt, 15.6 Amp PSUs.
D. Each PDU must use a C20-type connection.

Explanation:
The PowerEdge XE9680 server is equipped with power supply units (PSUs) that are essential for its operation. Here’s the power consumption information that the deployment engineer can provide: PSU Specifications: Each PowerEdge XE9680 server comes with​four 2800-Watt, 15.6 Amp PSUs1.
This specification is crucial for the data center manager to understand the power requirements for each server.
Total Power Requirement: With two servers per rack, each rack will have a total of​eight 2800-Watt PSUs. This information helps in calculating the total power draw for each rack.
Power Distribution Units (PDUs): While the number of PDUs required for high availability can vary, it’s important to note that the server’s PSUs feature a​C22 input socket1. The data center manager should ensure that the PDUs in the rack are compatible with this type of connection.
Power Planning: The data center manager must plan for the power needed to supply power to the four racks, considering the power draw of the servers and any additional equipment that will be installed.
By providing this detailed power consumption information, the deployment engineer assists the data center manager in planning for the appropriate power infrastructure to support the PowerEdge XE9680 servers.

Question#3

A deployment engineer is installing a PowerEdge XE8640 server in a rack with round holes. They cannot get the outer rail portion to fit flush with the rack frame.
What is the reason the outer rail is not flush with the frame?

A. The rail latch is not engaged.
B. The PowerEdge XE8640 does not support a round-hole rack.
C. A small offset is expected between the rail mounting post and the rack.
D. Weight has not been applied to the rail.

Explanation:
Understanding Rail Types and Compatibility:
Dell PowerEdge servers, including the XE8640, come with rail kits designed for specific types of racks. The rail kits are tailored to fit racks with square holes or threaded holes, depending on the model and configuration.
Compatibility with Round-Hole Racks:
The PowerEdge XE8640 does not support installation in round-hole racks. The rail kits provided with the XE8640 are designed for 4-post racks with square holes or 4-post threaded racks. Attempting to install these rails in a round-hole rack will result in improper fitment and stability issues. Common Installation Issues:
If the outer rail portion does not fit flush with the rack frame, it is often due to a compatibility issue with the rack type. Round-hole racks require specific rail kits that are different from those used for square or threaded hole racks.
Verifying Rack Type:
Before installation, verify the type of rack being used. Ensure that it matches the specifications outlined in the server's installation guide. Using the correct rack type ensures proper fitment and structural integrity.
Alternative Solutions:
If the current rack is a round-hole type, consider using a compatible rack with square or threaded holes for the XE8640. Alternatively, there might be adapters or conversion kits available that allow the use of standard rails in round-hole racks, although these are not typically recommended due to potential stability issues.
Reference and Documentation:
Refer to the Dell EMC PowerEdge XE8640 Installation and Service Manual for detailed information on rail and rack compatibility. This manual provides specifications for supported rack types and instructions for proper installation.
Reference: Dell EMC PowerEdge XE8640 Installation and Service Manual: This document provides comprehensive guidelines on the correct installation procedures and compatible rack types for the XE8640 server.
Dell EMC Technical Specifications Guide: Offers detailed specifications on the rack compatibility and rail options for Dell PowerEdge servers, ensuring proper installation and fitment