Question#1

You have to disable a switch that is connected to a port on your FAS2750. You notice that the LIFs that are associated with this port are migrated to a port that is not expected.
In this scenario, what would cause this behavior?

A. The network port is configured incorrectly.
B. The broadcast domain is configured incorrectly.
C. There are no online ports within the same failover group.
D. The network failover port is not licensed.

Explanation:
In ONTAP, LIF failover target selection is controlled by failover groups and failover policies. A key installation and validation concept is that ONTAP uses broadcast domains to simplify and automate failover-group membership. Specifically, ONTAP documents that when you create a broadcast domain, ONTAP automatically creates a failover group with the same name and manages it so that as ports are added or removed from the broadcast domain, they are also added or removed from the associated failover group.
Because of this coupling, if a LIF “moves to a port that is not expected,” the most direct and common cause is that the broadcast domain contains ports that do not belong there (or ports that should be in a different broadcast domain/IPspace). When the original port goes down (for example, because you disabled the connected switch), ONTAP looks for eligible failover targets in the LIF’s assigned failover group. If the broadcast domain was defined too broadly or incorrectly, the failover group will also be too broad, and ONTAP may pick a port that appears valid per configuration but is “unexpected” from the design intent.
Option C (“There are no online ports within the same failover group”) would more commonly result in no valid failover target (and therefore an outage) rather than a clean migration to an unexpected port; ONTAP even warns that without a valid target, an outage occurs during failover verification.
Option A is too generic and does not specifically explain why adifferentport becomes a valid target.
Option D is not a typical ONTAP networking root cause for LIF migration behavior .
Therefore, the behavior is best explained by an incorrectly configured broadcast domain.

Question#2

You are a NetApp Professional Services engineer. You have completed an ONTAP cluster installation and need to collect configuration information to enable creation of a Service Event Report (SER).
Which tool would you use?

A. Active IQ scheduled reports
B. NetAppDocs output report
C. ONTAP System Manager
D. Active IQ Config Advisor worksheet

Explanation:
Service Event Reports require standardized installation and configuration data. NetAppDocs generates structured output reports specifically designed for SER creation, including hardware, cabling, and configuration details. Other tools do not produce SER-formatted documentation.

Question#3

You used the system controller environment show command.
Which issue would be diagnosed with this command?

A. controller configuration issues
B. controller hardware issues
C. shelf cabling issues
D. controller version issues

Question#4

On which type of network interfaces are the cluster interconnect LIFs created?

A. on an FC or FCoE port
B. on an interface group
C. on a UTA port shared with other LIFs
D. on a physical port

Question#5

You were dispatched to install a cluster made up of FAS8060 and FAS8080 controllers. There are three FAS8060 controllers and three FAS8080 controllers.
Which solution would provide the largest possible cluster?

A. a cluster made up of two nodes
B. a cluster made up of four nodes
C. a cluster made up of five nodes
D. a cluster made up of six nodes

Explanation:
As part of the ONTAP SAN solution assessment domain, NetApp defines strict rules governing cluster composition and scalability. ONTAP clusters support a maximum of24 nodes, and within that limit, clusters can include different controller models, provided they are supported by the same ONTAP release and meet hardware compatibility requirements.
Both FAS8060and FAS8080controllers are supported within ONTAP clusters and can coexist in a single cluster configuration. NetApp installation documentation explicitly allows mixed-controller clusters as long as the controllers are compatible and running the same ONTAP version.
In this scenario, there are six total controllers available: three FAS8060 and three FAS8080. Since ONTAP supports heterogeneous clusters and there is no architectural limitation preventing all six controllers from participating, the largest possible cluster is achieved by including all six nodes. Smaller cluster sizes―two, four, or five nodes―are technically valid but do not meet the requirement of providing the largest possible cluster. The assessment objective focuses on maximizing usable resources while staying within supported configuration guidelines. Additionally, ONTAP automatically manages performance balancing and high availability across mixed-controller clusters. Each node pair forms an HA pair, and ONTAP ensures consistent data access across the entire cluster fabric.
Therefore, the correct answer is D, a cluster made up of six nodes.

Exam Code: NS0-185
Q & A: 120 Q&As         Updated:  Nov 06,2026

 

 Access Complete NS0-185 Preparation Material

What This NS0-185 Study Resource Helps You Do

Review Key Concepts

Review the technologies, products, processes, and practical skills covered by the current NS0-185 exam objectives.

Practice Scenario-Based Questions

Work through independently developed questions designed to strengthen your understanding of technical scenarios and decision-making.

Identify Knowledge Gaps

Use your results and the provided explanations to find weaker areas and focus your study more effectively.

How to Use This NS0-185 Preparation Material

Review the Exam Scope

Start by reviewing the topics covered by the NS0-185 exam. Compare them with the official exam objectives to understand the required technologies, operational tasks, and practical skills, then identify the areas that deserve the most attention.

Practice Independently

Complete a focused set of practice questions for each topic. On your first attempt, avoid referring to notes, answers, or other study resources so that you can evaluate your current understanding more accurately.

Study the Explanations

Review the answers and explanations after completing each practice session. Understand why the correct option is appropriate for the given scenario and why the other options may be incorrect or less suitable.

Close Knowledge Gaps

Keep track of incorrect answers, unfamiliar concepts, and weaker knowledge areas. Review these topics using official documentation and practical experience, then answer the related questions again to reinforce your understanding and monitor your progress.

Independent NS0-185 Preparation Resource

CertQueen independently develops its certification study materials for educational purposes. The practice questions are not copied from, recalled from, or presented as live or official exam questions.

CertQueen is not affiliated with, endorsed by, sponsored by, or authorized by any certification provider. Certification names, exam codes, product names, and related trademarks are the property of their respective owners and are referenced only for identification and educational purposes.

Exam Code: NS0-185
Q & A: 120 Q&As
Updated:  Nov 06,2026

 

 Access Complete NS0-185 Preparation Material